Cart (Loading....) | Create Account
Close category search window
 

Preliminary results from the new large-area PETRRA positron camera

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

8 Author(s)
Duxbury, D.M. ; Dept. of Phys., R. Marsden Hosp., Sutton, UK ; Ott, R.J. ; Flower, M.A. ; Erlandsson, K.
more authors

The PETRRA positron camera is based on the use of BaF2 scintillators interfaced to large area multiwire proportional chambers filled with a photo-sensitive vapour (TMAE). The camera consists of two 60 cm×40 cm annihilation photon detectors mounted on a rotating gantry. Initial measurements with the camera show that the spatial resolution is ~6.5±1 mm FWHM all through the field-of-view, and the timing resolution is between 7 ns and 10 ns FWHM. Detection efficiency for annihilation photons is ~30% per detector. The count rates obtained, by using a 20 cm diameter by 11 cm long water filled phantom containing 18F, were ~1.35×106 singles and ~1.2×105 cps raw coincidences at which point data-rates are limited by the dead-time in the readout system. The randoms rate varies between 5 and 50% with activity in the field of view of 10-100 MBq (0.27-2.7 mCi) with a timing gate of 20 ns. Initial results show that the randoms corrected sensitivity is >3-4 kcps/kBq/ml (120-150 kcps/μCi/ml) for activities up to 30 MBq (0.81 mCi) in a 20 cm diameter water-filled phantom. However, these values include a high (60%) scatter fraction due to detector support structures. The camera has not yet been fully optimised and it is expected that the performance will substantially improve by further tuning and a reduction in the scattering structures. With a 40 cm axial FoV the camera is ideally suited to whole-body imaging in oncology

Published in:

Nuclear Science, IEEE Transactions on  (Volume:46 ,  Issue: 4 )

Date of Publication:

Aug 1999

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.