By Topic

Extraction algorithm of pulmonary fissures using thin-section CT images

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

9 Author(s)
M. Kubo ; Dept. of Opt. Sci., Tokushima Univ., Japan ; N. Niki ; S. Nakagawa ; K. Eguchi
more authors

In this paper, the authors describe a new automatic extraction algorithm of the pulmonary major and minor fissures from three dimensional (3-D) chest thin-section images of helical computed tomography (CT). These fissures are useful for the analysis of pulmonary conformation and the diagnosis of lung cancer. This algorithm consists mainly of the correction and the emphasis of a 2-D linear shadow. The authors applied the proposed algorithm to 25 sets of CT examinations of 12 patients. The results showed that major and minor fissures can be extracted by the proposed algorithm, without reference to linear artifacts on axial CT images by the beam hardening effect, and the motion artifacts by the cardiac beat

Published in:

Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE  (Volume:3 )

Date of Conference:

1998