Dynamic regional cerebral blood flow SPECT processing using the Karhunen-Loeve transform for the reduction of noise and computational load

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Pretorius, P.H. ; Massachusetts Univ. Med. Center, Worcester, MA, USA ; Glick, S.J. ; Narayanan, V.M. ; Kong, M.A.
more authors

The Karhunen-Loeve (K-L) transform can be used to achieve a reduction in noise and computational load for dynamic acquisitions. This study evaluated the use of the K-L transform in processing Xe-133 dynamic brain SPECT images using both simulated and clinical data. A simple 3D dynamic brain phantom, consisting of five different regions that represents high and low regional cerebral blood flow (RCBF) embedded in a low flow background were used in the simulation study. An analytical 3D projector was used to realistically simulate 24 time sequences over a 6 minute period (15 sec/projection set) to represent dynamic brain blood flow. Poisson noise was added. Two implementations of the K-L transform were investigated. Method 1 consisted of selecting the first two principle components in K-L space before inverse transformation and conventional OSEM reconstruction. Method 2 consisted of retaining the first three principle components in K-L space, reconstructing using MAP AB-EMML with Gibbs regularization. Three patients referred to the clinic undergone routine Xe-133 brain blood flow SPECT studies. In comparison with conventional processing K-L Method 1 gives similar RCBF values in all the regions while a bias was introduced with K-L Method 2. Noise reduction and an order of magnitude decrease in computational load were obtained. In patient data, K-L Method 1 showed similar results as the conventional method for high blood flow values and have improved contrast of low blood flow areas