Heavy ion linear energy transfer measurements during single event upset testing of electronic devices

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Zajic, V. ; Brookhaven Nat. Lab., Upton, NY, USA ; Thieberger, P.

A heavy ion beam diagnostic system installed at the Brookhaven Single Event Upset Test Facility is described. Calibration of the system with the help of a-particles, essential for linear energy transfer (LET) measurements, is discussed. Measured LET values for 20 different ions, including 7Li, 9B, 12C, 16O, 19F, 28Si, 32S, 35Cl, 40Ca, 45Sc, 48Ti, 56Fe, 58Ni, 63Cu, 74Ge, 79Br, 107Ag, 127I, 197Au, and 235U, with energies between 0.5 and 8.5 MeV/AMU but not exceeding 400 MeV for the heaviest ions, are presented in both graphical and numerical forms. Results are compared to predictions of the TRIM-90 simulation program, with an average difference between the measured and calculated values of 2±6%