3 Author(s)
Kimoto, A. ; Dept. of Electron. & Electr. Eng., Saga Univ., Japan ; Matsuoka, Y. ; Shida, K.

The purpose of study is the non-invasive imaging of temperature distribution by estimating the permittivity distribution based on the measurement of capacitance of which permittivity-temperature characteristic is confirmed. To promote the study, a measurement method involving changing the size of supplementary electrode plates has been proposed. The reconstruction of the temperature-change distribution of a brain-phantom using the proposed method is described