Close category search window
 

A transducer for the measurement of finger joint moments

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Kilgore, K.L. ; Case Western Reserve Univ., Cleveland, OH, USA ; Lauer, R.T. ; Peckham, P.H.

A device capable of simultaneously measuring the isometric moments generated about the metacarpophalangeal (MP), proximal interphalangeal (PTP), and distal interphalangeal (DIP) joints of all four fingers has been developed. The design utilizes a four-bar linkage to transmit moments, but not forces, to the device. This linkage allows the same device to fit a wide range of hand sizes without recalibration. The device was constructed out of aluminum bars which are strapped to each joint segment and to the back of the hand. Strain gauges mounted to the aluminum bars measure the bending moment on the device, which is directly related to the moment applied about the joint center of rotation. Because of the unique design of the device, it is not necessary to have accurate measurements of the joint center of rotation in order to get accurate moment information. A single device is capable of generating independent measurement of MP extension/flexion, PIP extension/flexion, and DIP extension/flexion. Four of these devices can be used to make simultaneous measurements of all the moments generated by all four fingers. The device also acts as a splint, allowing each joint to be positioned and locked at any angle through the range of motion of the joint. The device is accurate to within ±5.6% of each reading for moments from 10 N·cm to 100 N·cm and within ±2.0 N·cm for moments of 10 N·cm or less. If the device configuration is constrained, the accuracy can be improved to ±0.8% of full scale (100 N·cm) and ±0.21 N·cm for moments of 10 N·cm or less. The device can measure both flexion and extension moments up to 100 N·cm, and can allow the joints to be fixed at any angle from approximately 10 to 800

Published in:

Rehabilitation Engineering, IEEE Transactions on  (Volume:6 ,  Issue: 4 )

Date of Publication:

Dec 1998

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.