Cart (Loading....) | Create Account
Close category search window
 

The design and performance of a simultaneous transmission and emission tomography system

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

9 Author(s)
Gullberg, G.T. ; Dept. of Radiol., Utah Univ., Salt Lake City, UT, USA ; Morgan, H.T. ; Zeng, G.L. ; Christian, P.E.
more authors

A commercial three-detector single-photon emission computed tomography (SPECT) system that enables simultaneous acquisition of transmission and emission data without increasing patient scanning time has been designed and manufactured. This system produces a reconstructed attenuation coefficient distribution that can be used to correct for photon attenuation in the emission reconstruction. The three detectors with fan-beam collimators are mounted to the gantry in a triangular arrangement. A transmission line source assembly was mounted at the focal line of one of the detectors and controlled to move in synchrony with the opposing fan-beam collimator. Data from transmission and emission sources at different energies were acquired in one detector, while the other two simultaneously acquired emission data. A transmission source of 153Gd was used with 99mTc-labeled radiopharmaceuticals, and 57Co was used with 201Tl. Algorithms were developed to subtract crosstalk between transmission and emission energy windows in all three detectors. A transmission maximum-likelihood iterative algorithm was used to reconstruct the attenuation distribution, which was used in combination with an iterative maximum-likelihood expectation-maximization algorithm to compensate for the attenuation of the projection of the emission distribution. The results in phantom studies displayed greater uniformity of activity with attenuation-corrected reconstruction. This was demonstrated visually and quantitatively by using anterior-to-inferior ratios close to one and low spatial %rms error as a measure of improved uniformity

Published in:

Nuclear Science, IEEE Transactions on  (Volume:45 ,  Issue: 3 )

Date of Publication:

Jun 1998

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.