By Topic

The Control of Self-Propelled Microjets Inside a Microchannel With Time-Varying Flow Rates

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Islam S. M. Khalil ; MIRA-Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands ; Veronika Magdanz ; Samuel Sanchez ; Oliver G. Schmidt
more authors

We demonstrate the closed-loop motion control of self-propelled microjets inside a fluidic microchannel. The motion control of the microjets is achieved in hydrogen peroxide solution with time-varying flow rates, under the influence of the controlled magnetic fields and the self-propulsion force. Magnetic dipole moment of the microjets is characterized using the U-turn and the rotating field techniques. The characterized magnetic dipole moment has an average of 1.4×10-13 A.m2 at magnetic field, linear velocity, and boundary frequency of 2 mT, 100 μm/s, and 25 rad/s, respectively. We implement a closed-loop control system that is based on the characterized magnetic dipole moment of the microjets. This closed-loop control system positions the microjets by directing the magnetic field lines toward the reference position. Experiments are done using a magnetic system and a fluidic microchannel with a width of 500 μm. In the absence of a fluid flow, our control system positions the microjets at an average velocity and within an average region-of-convergence (ROC) of 119 μm/s and 390 μm, respectively. As a representative case, we observe that our control system positions the microjets at an average velocity and within an average ROC of 90 μm/s and 600 μm and 120 μm/s and 600 μm when a flow rate of 2.5 μl/min is applied against and along the direction of the microjets, respectively. Furthermore, the average velocity and ROC are determined throughout the flow range (0 to 7.5 μl/min) to characterize the motion of the microjets inside the microchannel.

Published in:

IEEE Transactions on Robotics  (Volume:30 ,  Issue: 1 )