Suppression of Quantization-Induced Convergence Error in Pipelined ADCs With Harmonic Distortion Correction

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

The purchase and pricing options are temporarily unavailable. Please try again later.
2 Author(s)
Nevena Rakuljic ; Department of Electrical and Computer Engineering, University of California at San Diego, La Jolla, CA, USA ; Ian Galton

Harmonic Distortion Correction (HDC) is one of two published digital background calibration techniques that compensate for residue amplifier nonlinearity in pipelined ADCs. The techniques make it possible to reduce the gains and bandwidths, and therefore the power dissipations, of the op-amps that make up the residue amplifiers without sacrificing pipelined ADC accuracy. Unfortunately, the previously published techniques fail to operate properly when they measure residue amplifier distortion for certain pipelined ADC input signals, most notably input signals with small peak-to-peak variations about certain constant values. This paper identifies the cause of the problem, quantifies its effects, and provides an all-digital solution applicable to the HDC technique.

Published in:

IEEE Transactions on Circuits and Systems I: Regular Papers  (Volume:60 ,  Issue: 3 )