Close category search window
 

Calibration and performance assessment of a temperature sensor prototype using a 1-point calibration procedure

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1063/1.4767244 

This study aims to assess the relevance of 1-point calibration procedure, within the framework of the development of a new telemetric temperature sensor. The criteria used for performance assessment were the level of accuracy, and the time of inertia of the temperature sensor prototype (TSP) tested. First, the stability of the calibration bath was assessed. Then, the accuracy of 16 prototypes was evaluated for 7 target temperatures (ranging from 29 °C to 45 °C). Finally, the inertia of TSP response was evaluated while increasing and decreasing the bath temperature. The difference between prototype and target temperature increases as bath temperature moves away from 37 °C; however, the accuracy of the sensor conforms to applicable standards. Most TSP remain in the range of ±0.2 °C for each temperature level tested, but a linear, decreasing slope is observed; prototypes underestimate high temperatures and overestimate low temperatures. Data from time of inertia assessment show that probes were within the range of ±0.2 °C from the target temperature with a maximal delay of 150 s which satisfy standard norms. However, results indicate that a 1-point calibration procedure of the sensors appears non optimal, a 2-point calibration procedure should be performed to avoid the observed temperature data slope.

Published in:
Review of Scientific Instruments  (Volume:83 ,  Issue: 11 )

Date of Publication: Nov 2012

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.