Improvement of the differential busbar characteristic to avoid false operation during to CT saturation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

1 Author(s)
Eissa, M.M. ; Electr. Eng. Dept., Helwan Univ., Cairo, Egypt

The proposed technique is based on extracting the windowed wavelet transform of fault generated transients to distinguish between faults in a busbar protection zone from those outside the zone, particularly in case of early and severe current transformer (CT) saturation. Most given techniques are tending to block the differential measurement during the portion of the cycle that a current transformer is saturated. Some other techniques bring more meaning to the breakpoint settings of the operating characteristic. The traditional differential concept is based on the current magnitude for estimating the restraining and biasing values. The significant imbalance comes from the secondary current of a current transformer with a resistive burden which collapses to zero when saturation occurs and it remains at zero until the time when the next zero crossing would have occurred. The study describes a new technique with improved characteristic and the differential concept does not depend on the current magnitude. The wavelet transform (WT) depends on high frequencies of the faulted signal produced owing to CT saturation. The proposed WT is based on Mexican basis function that was found to be an excellent discriminant for identifying the fault signals during the CT saturation. The time and frequency information during saturation are obtained rather than the current magnitude.

Published in:

Generation, Transmission & Distribution, IET  (Volume:6 ,  Issue: 10 )

Date of Publication:

October 2012

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.