Correlation Between Electrode-Tissue Impedance and Motion Artifact in Biopotential Recordings

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

8 Author(s)
Buxi, D. ; Body Area Networks Program, Holst Centre/IMEC, Eindhoven, Netherlands ; Sunyoung Kim ; van Helleputte, N. ; Altini, M.
more authors

Ambulatory monitoring of the electrocardiogram (ECG) is a highly relevant topic in personal healthcare. A key technical challenge is overcoming artifacts from motion in order to produce ECG signals capable of being used in clinical diagnosis by a cardiologist. An electrode-tissue impedance is a signal of significant interest in reducing the motion artifact in ECG recordings on the go. A wireless system containing an ultralow-power analog front-end ECG signal acquisition, as well as the electrode-tissue impedance, is used in a validation study on multiple subjects. The goal of this paper is to study the correlation between motion artifacts and skin electrode impedance for a variety of motion types and electrodes. We have found that the correlation of the electrode-tissue impedance with the motion artifact is highly dependent on the electrode design the impedance signal (real, imaginary, absolute impedance), and artifact types (e.g., push or pull electrodes). With the chosen electrodes, we found that the highest correlation was obtained for local electrode artifacts (push, pull, electrode) followed by local skin (stretch, twist, skin) and global artifacts (walk, jog, jump). The results show that the electrode-tissue impedance can correlate with the motion artifacts for local disturbance of the electrodes and that the impedance signals can be used in motion artifact removal techniques such as adaptive filtering.

Published in:

Sensors Journal, IEEE  (Volume:12 ,  Issue: 12 )