Partial-Body SAR Calculations in Magnetic-Resonance Image (MRI) Scanning Systems [Telecommunications Health and Safety]

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Zhangwei Wang ; GE Healthcare, Aurora, OH, USA ; Lin, J.C.

To ensure that the radio-frequency (RF) energy absorbed by human subjects during MRI does not produce any harmful health effects to the patient - including local thermal damage or whole-body thermoregulatory challenges - regulatory entities have set limits on the maximum local, partial-body, and whole-body specific absorption rates (SAR) of RF energy. This paper discusses numerical calculations of partial-body and local peak specific absorption rate. These are compared to currently used partial-body average SAR calculations in specifying the partial-body average SAR limits and local peak SAR that are based on body mass. Calculations using the fi nite-difference time-domain numerical method and 2 mm resolution Visible Human models showed that while there were some differences in the two magnetic field strengths (1.5 T and 3.0 T or 64 MHz and 128 MHz), the gross patterns of SAR distribution were similar for both 1.5 T and 3.0 T birdcage MRI coils. Computed partial-body SARs were higher than those from curve-fitting formulas used for male and female local peak SARs (in 1 g or 10 g averaging regions), and were considerably greater than specified in the regulatory limits for both whole-body and partial body SARs. In all the cases studied, with data both for 1.5 T and 3.0 T birdcage MRI coils, computed partial-body SARs exceeded values given by regulatory limits for the patient. The local peak SARs may exceed values specified in IEC and FDA regulatory limits for both whole-body and partial-body SARs. This was because the mass-ratio-based calculations are not directly related to SARs in specific body tissues.

Published in:

Antennas and Propagation Magazine, IEEE  (Volume:54 ,  Issue: 2 )