NDT of high speed fine particles by high Tc SQUID

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Nagaishi, T. ; Res. Labs., Sumitomo Electr. Ind. Ltd., Itami, Japan ; Kugai, H. ; Toyoda, H. ; Itozaki, H.

We detected moving magnetized fine particles with high Tc SQUIDs. The output signals of SQUIDs were investigated with various particle speeds. It was found that the signal decreases less than 20% with an increase of particle speed from 10 to 500 m/min. An iron particle of 50 /spl mu/m diameter could be detected by the SQUID. The high Tc SQUID had a trilayered 15-turn flux transformer. It has a magnetic field resolution of 48 fT Hz/sup -1/2/ at white noise level and a magnetic field capture area of 2.7 mm/sup 2/.