Close category search window
 

Multilead Measurement System for the Time-Domain Analysis of Bioimpedance Magnitude

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Gracia, J. ; Dept. of Biomed. Eng., Tampere Univ. of Technol., Tampere, Finland ; Seppa, V.P. ; Viik, J. ; Hyttinen, J.

Bioimpedance measurement applications range from the characterization of organic matter to the monitoring of biological signals and physiological parameters. Occasionally, multiple bioimpedances measured in different locations are combined in order to solve complex problems or produce enhanced physiological measures. The present multilead bioimpedance measurement methods are mainly focused on electrical impedance tomography. Systems designed to suit other multilead applications are lacking. In this study, a novel multilead bioimpedance measurement system was designed. This was particularly aimed at the time-domain analysis of bioimpedance magnitude. Frequency division multiplexing was used to avoid overlapping between excitation signals; undersampling, to reduce the hardware requirements; and power isolated active current sources, to reduce the electrical interactions between leads. These theoretical concepts were implemented on a prototype device. The prototype was tested on equivalent circuits and a saline tank in order to assess excitation signal interferences and electrical interactions between leads. The results showed that the proposed techniques are functional and the system's validity was demonstrated on a real application, multilead impedance pneumography. Potential applications and further improvements were discussed. It was concluded that the novel approach potentially enables accurate and relatively low-power multilead bioimpedance measurements systems.

Published in:
Biomedical Engineering, IEEE Transactions on  (Volume:59 ,  Issue: 8 )

Date of Publication: Aug. 2012

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.