Cart (Loading....) | Create Account
Close category search window
 

Evaluation of a MEMS-Based Dual Metal-Layer Thin-Film Microelectrode Array for Suprachoroidal Electrical Stimulation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

10 Author(s)
Xiaohong Sui ; Sch. of Biomed. Eng., Shanghai Jiao Tong Univ., Shanghai, China ; Jingjing Sun ; Liming Li ; Chuanqing Zhou
more authors

A double metal-layer thin-film platinum microelectrode array was fabricated for implantation between sclera and choroid based on MEMS processing techniques and photosensitive polyimide material. The array was composed of 60 stimulating sites (6 × 10) and four selectable returning electrodes. The diameter of each stimulating electrode was 350 μm with a center-to-center spacing of 750 μm. The transient voltage responses of the electrode to current pulse stimulation indicated a charge-injection capacity greater than 52.1 μC/cm2. Acute in vivo animal experiments showed that the implicit time of electrically evoked potentials (EEPs) was 17.09 ± 1.45 ms at a threshold current of 25.55 ± 5.43 μA for a full-row of simultaneously stimulated electrodes (i.e. current applied simultaneously to each of the 10 electrodes). Individual electrode stimulation threshold was 48.57 ± 6.90 μA. The corresponding threshold charge densities were 13.28 ± 2.82 μC/cm2 and 25.24 ± 3.59 μC/cm2, respectively. The spatial spread of the maximally recorded P1 response in the EEPs indicated a correspondence between the retinal stimulation site and the focal response location in the cortex. This method of array fabrication is suitable for acute suprachoroidal stimulation, and has a potential use for the fabrication of a visual prosthesis.

Published in:

Neural Systems and Rehabilitation Engineering, IEEE Transactions on  (Volume:21 ,  Issue: 4 )

Date of Publication:

July 2013

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.