3 Author(s)
Pancotti, Anthony P. ; MSNW LLC., 8551 154th Ave., Redmond, Washington 98052, USA ; Gilpin, Matthew ; Hilario, Martin S.

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1063/1.3690385 

With the progression of high-power electric propulsion and high thrust-to-power propulsions system, thrust stand diagnostics require high-fidelity calibration systems that are accurate over a large-range of thrust levels. Multi-mode and variable Isp propulsion devices also require that a single stand be capable of measuring thrust from 10's of uNs to 100's of mNs. While the torsional thrust stand mechanic and diagnostics are capable of operating over such a large range, current pulsed calibration schemes are typically limited to a few orders of magnitude of dynamic range. In order to develop a stand with enough dynamic range, two separate calibration methods have been examined and compared to create a combined system. Electrostatic fin (ESF) and piezoelectric impact hammer (PIH) calibration systems were simultaneously tested on a large scale torsional thrust stand system. The use of the these two methods allowed the stand to be calibrated over four orders of magnitude, from 0.01 mNs to 750 mNs. The ESF system produced linear results within 0.52% from 0.01 mNs to 20 mNs, while the PIH system extended this calibration range from 10 mNs to 750 mNs with an error of 0.99%. The two calibration methods agreed within 4.51% over their overlapping range of 10–20 mNs.

Published in:
Review of Scientific Instruments  (Volume:83 ,  Issue: 3 )

Date of Publication: Mar 2012

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.