C37.13-2008  -  IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures

Superseded by IEEE Std C37.13-2015 (Revision of IEEE Std C37.13-2008)
StatusInactive  -  Superseded

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

This document is also available as part of a bundle
Options Non-Member Member
$75.0 $65.0
$162.0 $127.0
IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures - RedlineView Bundle Details
Item has been added to the cart.

Bundle Details

IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures - Redline

This bundle includes the following items:
  • C37.13-2008 selected IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures
Non Member: $162.0 Member: $127.0
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

The following enclosed low-voltage ac power circuit breakers are covered in this standard: a) stationary or draw-out type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 635 V (600 V for units incorporating fuses), 508 V, and 254 V for application on systems having nominal voltages of 600 V, 480 V, and 240 V; b) unfused or fused circuit breakers; c) manually or power operated; and d) with or without electromechanical or electronic trip devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed in this standard.

Scope
The scope of this standard includes the following enclosed low-voltage ac power circuit breakers:a) Stationary or drawout type of two-, three-, or four-pole construction with one or more rated maximum voltages of 635 V (600 V for units incorporating fuses), 508 V, and 254 V for application on systems having nominal voltages of 600 V, 480 V, and 240 Vb) Unfused or fused typec) Manually operated or power operated, with or without electromechanical or electronic trip devicesd) Fused drawouts consisting of current-limiting fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a nonintegrally fused circuit breakerNOTEIn this standard, the term circuit breaker shall mean enclosed low-voltage ac power circuit breaker, either fused or unfused. The term unfused circuit breaker shall mean a circuit breaker without either integrally or nonintegrally mounted fuses, and the term fused circuit breaker shall mean a circuit breaker incorporating currentlimiting fuses.This document applies to both integrally and nonintegrally fused circuit breakers.