An Experiment-Based Approach for Predicting Positron Emitter Distributions Produced During Therapeutic Ion Irradiation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Priegnitz, M. ; Inst. of Radiat. Phys., Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany ; Fiedler, F. ; Kunath, D. ; Laube, K.
more authors

In-beam positron emission tomography (PET) is a valuable method for a beam-delivery independent dose monitoring in radiation therapy with ion beams. Up to now, its clinical feasibility has been demonstrated for patient irradiation with carbon ions. From radiobiological point of view it is highly desirable to perform tumor irradiation also with other light ions. To extend the application of in-beam PET also to these ions, extensive knowledge about positron emitter production via nuclear fragmentation reactions during ion irradiation is necessary. To model the positron emitter production correctly, cross sections for all possible nuclear reactions occurring in the tissue during irradiation and leading to positron emitters are required. Since these cross sections are available only for a few reaction channels in the required energy range, a novel approach for estimating the positron emitter production from experimental data is introduced. The prediction of positron emitter distributions is based on depth dependent thick target yields, which are derived by linear superposition of measured yields in water, graphite and polyethylene as reference materials. Results on the prediction of positron emitter distributions in polymethyl methacrylate (PMMA) as well as inhomogeneous targets induced by lithium and carbon irradiation are presented. By comparison with data deduced from experiments, it is shown that a rather accurate prediction of positron emitter distribution is feasible using this method.