By Topic

Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

7 Author(s)
Krieger, A. ; Dept. of Mech. Eng., Johns Hopkins Univ., Baltimore, MD, USA ; Sang-Eun Song ; Cho, N.B. ; Iordachita, I.I.
more authors

This paper reports the design, development, and magnetic resonance imaging (MRI) compatibility evaluation of an actuated transrectal prostate robot for MRI-guided needle intervention in the prostate. The robot performs actuated needle MRI guidance with the goals of providing 1) MRI compatibility; 2) MRI-guided needle placement with accuracy sufficient for targeting clinically significant prostate cancer foci; 3) reducing interventional procedure times (thus increasing patient comfort and reducing opportunity for needle targeting error due to patient motion); 4) enabling real-time MRI monitoring of interventional procedures; and 5) reducing the opportunities for error that arise in manually actuated needle placement. The design of the robot, employing piezoceramic-motor actuated needle guide positioning and manual needle insertion, is reported. Results of an MRI compatibility study show no reduction of MRI signal-to-noise ratio (SNR) with the disabled motors. Enabling the motors reduces the SNR by 80% without radio frequency (RF) shielding, but the SNR is only reduced by 40-60% with RF shielding. The addition of RF shielding is shown to significantly reduce image SNR degradation caused by the presence of the robotic device. An accuracy study of MRI-guided biopsy needle placements in a prostate phantom is reported. The study shows an average in-plane targeting error of 2.4 mm with a maximum error of 3.7 mm. These data indicate that the system's needle targeting accuracy is similar to that obtained with a previously reported manually actuated system, and is sufficient to reliably sample clinically significant prostate cancer foci under MRI guidance.

Published in:

Mechatronics, IEEE/ASME Transactions on  (Volume:18 ,  Issue: 1 )