Monitoring of thermal ablation therapy based on shear modulus changes: Shear wave thermometry and shear wave lesion imaging

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Arnal, Bastien ; Inst. Langevin, Univ. Paris 7, Paris, France ; Pernot, M. ; Tanter, M.

The use of High intensity Focused Ultrasound (HIFU) for non invasive therapy requires improving real-time monitoring of the lesion formation during treatment, to avoid damage of the surrounding healthy tissues. The goal of this study is to show the feasibility of a full ultrasound approach that relies on the real-time and quantitative assessment of the changes in tissue elasticity both to map temperature and monitor the lesion formation. HIFU treatment and monitoring was performed using a confocal set made up of a 8MHz ultrasound diagnostic probe (Vermon) and a 2.5MHz single element transducer focused at 30mm (Imasonic) on ex-vivo samples. US-temperature estimation based on speckle tracking was combined with Supersonic Shear Wave Imaging (SWI) on the same device (Aixplorer, SuperSonic Imagine). The SWI sequence consisted in successive shear waves induced at different lateral positions. The shear wave propagation was acquired at 17000 frames/s, from which the elasticity map was recovered. HIFU sonications were interleaved with fast imaging acquisitions allowing a duty cycle of more than 90%. A low-temperature elevation calibration phase is performed using a dedicated sequence just before the actual treatment. A full elasticity and temperature mapping was achieved every 3 seconds during the treatment. Below 40°C, tissue stiffness was found to reversibly decrease with temperature at the focal zone (-0.86kPa/°C). US-temperature was highly correlated to stiffness variation maps (correlation coefficient: 0.91-0.97). The linear dependence of elasticity changes below 50°C enables to perform thermometry imaging directly from elasticity changes maps. Then, for higher temperatures, lesion formation induced a very strong increase of the elastic modulus in the focal zone. Thus, the same method allowed a complete follow-up of the tissue during treatment in two particular regimes: shear wave thermometry during heating and shear wave lesion imaging when the - - thermal threshold was reached. Shear wave temperature imaging allows temperature to be estimated up to 50°C. Moreover, SWT was shown to be very low sensitive to motion (for tissue motion less than 2 cm/s) allowing temperature estimation on moving area. Finally, the size of the thermal lesions determined on the stiffness maps correlated strongly with optical contrast of tissue cuts (+/-0.15mm). Shear Wave Thermometry is a novel reliable approach for ultrasound based monitoring of thermal ablation. SWT can be combined with shear wave lesion imaging to achieve a complete follow up of the treatment.

Published in:

Ultrasonics Symposium (IUS), 2010 IEEE

Date of Conference:

11-14 Oct. 2010

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.