A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Ibrahim, A.O. ; Dept. of Electr. & Comput. Eng., Univ. of Waterloo, Waterloo, ON, Canada ; Thanh Hai Nguyen ; Dong-Choon Lee ; Su-Chang Kim

This paper proposes a low-voltage ride-through technique of a doubly fed induction generator (DFIG) wind turbine system using a dynamic voltage restorer (DVR). For effective control of the DVR, digital all-pass filters are used for extracting the positive-sequence component from the unbalanced grid voltage since they have the advantages of giving a desired phase shift and no magnitude reduction over conventional low- or high-pass filters. Using the positive-sequence component, the phase angles for the positive- and negative-sequence components of the grid voltage are derived. A control algorithm for the DVR that is dual voltage controllers only is implemented for the two sequence components in the dq synchronous reference frame. In order to achieve the power rating reduction of the DVR, the stator power reference for the DFIG is reduced during faults. In addition, a control scheme of pitch angle system is applied to stabilize the operation of the wind turbine system in the event of grid faults. PSCAD/EMTDC simulations show the effectiveness of the proposed technique and a feasibility of reducing the power rating of DVR for the fault ride-through capability of DFIG. The validity of the proposed control scheme for the DVR has also been verified by experimental results.

Published in:
Energy Conversion, IEEE Transactions on  (Volume:26 ,  Issue: 3 )

Date of Publication: Sept. 2011