Functional neuromuscular stimulation controlled by surface electromyographic signals produced by volitional activation of the same muscle: adaptive removal of the muscle response from the recorded EMG-signal

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Sennels, S. ; Dept. of Math. Modeling, Tech. Univ. Denmark, Lyngby, Denmark ; Biering-Sorensen, F. ; Andersen, O.T. ; Hansen, S.D.

In order to use the volitional electromyography (EMG) as a control signal for the stimulation of the same muscle, it is necessary to eliminate the stimulation artifacts and the muscle responses caused by the stimulation. The stimulation artifacts, caused by the electric field in skin and tissue generated by the stimulation current, are relatively easy to eliminate by shutting down the EMG-amplifier at the onset of the stimulation pulses. The muscle response is a nonstationary signal, therefore, an adaptive linear prediction filter is proposed. The filter is implemented and for three filter lengths tested on both simulated and real data. The filter performance is compared with a conventional fixed comb filter. The simulations indicate that the adaptive filter is relatively insensitive to variations in amplitude of the muscle responses, and for all filter lengths produces a good filtering. For variations in shape of the muscle responses and for real data, an increased filter performance can be achieved by increasing the filter length. Using a filter length of up to seven stimulation periods, it is possible to reduce real muscle responses to a level comparable with the background noise. Using the shut-down circuit and the adaptive filter both the stimulation artifacts and the muscle responses can be effectively eliminated from the EMG signal from a stimulated muscle. It is therefore possible to extract the volitional EMG from a partly paralyzed muscle and use it for controlling the stimulation of the same muscle

Published in:

Rehabilitation Engineering, IEEE Transactions on  (Volume:5 ,  Issue: 2 )