Cart (Loading....) | Create Account
Close category search window
 

Improved contrast-to-noise ratio of photon counting clinical x-ray CT images using a model-selection based approach

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Srivastava, S. ; Sch. of Med., Russell H. Morgan Dept. of Radiol. & Radiol. Sci., Johns Hopkins Univ., Baltimore, MD, USA ; Taguchi, K.

Energy sensitive photon counting x-ray detectors (PCXD) [1] have many advantages over energy-integrating x-ray detectors (EIXD) in x-ray computed tomography (CT), such as the ability to measure the spectrum of x-ray beams. When such PCXDs are operated under a high count rate in clinical scanners, coincident photons would distort the recorded energy spectrum due to the limited speed of the detector. To compensate for the spectrum distortions, we have developed analytical models for them [3] and integrated one such model into an image reconstruction process using a sinogram restoration framework [6]. In this method, the attenuation of the object was modeled as a sum of line integrals of N basis functions, where N was fixed at 3 for the entire sinogram when a contrast agent is involved. The method allowed us to reconstruct accurate images, compensating for the effect of spectrum distortion of PCXD; however, the contrast-to-noise (CNR) of the images were only comparable to that obtained by EIXDs. We believe the main reason is an increased statistical uncertainty in the estimated line integrals introduced by the 3rd basis function. In this paper, we propose a method to improve the CNR by employing the fewest number of basis functions Nm (≤ N) as necessary for an individual sinogram ray. Our simulation studies indicate that the CNR achieved for a Gd-based contrast agent by PCXDs could be 12% better than the conventional method of [6], and 28% better than EIXDs for scans with similar number of x-ray photons, which points to a dose reduction of 20% and 39% respectively.

Published in:

Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE

Date of Conference:

Oct. 30 2010-Nov. 6 2010

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.