By Topic

Optimal Rebinning of Time-of-Flight PET Data

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Sangtae Ahn ; Signal & Image Process. Inst., Univ. of Southern California, Los Angeles, CA, USA ; Sanghee Cho ; Quanzheng Li ; Yanguang Lin
more authors

Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin TOF data into a lower dimensional format. We have recently developed Fourier rebinning methods for mapping TOF data into non-TOF formats that retain substantial SNR advantages relative to sinograms acquired without TOF information. However, mappings for rebinning into non-TOF formats are not unique and optimization of rebinning methods has not been widely investigated. In this paper we address the question of optimal rebinning in order to make full use of TOF information. We focus on FORET-3D, which approximately rebins 3D TOF data into 3D non-TOF sinogram formats without requiring a Fourier transform in the axial direction. We optimize the weighting for FORET-3D to minimize the variance, resulting in H2-weighted FORET-3D, which turns out to be the best linear unbiased estimator (BLUE) under reasonable approximations and furthermore the uniformly minimum variance unbiased (UMVU) estimator under Gaussian noise assumptions. This implies that any information loss due to optimal rebinning is as a result only of the approximations used in deriving the rebinning equation and developing the optimal weighting. We demonstrate using simulated and real phantom TOF data that the optimal rebinning method achieves variance reduction and contrast recovery improvement compared to nonoptimized rebinning weightings. In our preliminary study using a simplified simulation setup, the performance of the optimal rebinning method was comparable to that of fully 3D TOF MAP.

Published in:

Medical Imaging, IEEE Transactions on  (Volume:30 ,  Issue: 10 )