By Topic

A Novel Approach Using Time–Frequency Analysis of Pulse-Oximeter Data to Detect Progressive Hypovolemia in Spontaneously Breathing Healthy Subjects

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

8 Author(s)
Selvaraj, N. ; Dept. of Biomed. Eng., Worcester Polytech. Inst., Worcester, MA, USA ; Shelley, K.H. ; Silverman, D.G. ; Stachenfeld, N.
more authors

Accurate and early detection of blood volume loss would greatly improve intraoperative and trauma care. This study has attempted to determine early diagnostic and quantitative markers for blood volume loss by analyzing photoplethysmogram (PPG) data from ear, finger, and forehead sites with our high-resolution time-frequency spectral (TFS) technique in spontaneously breathing healthy subjects (n=11) subjected to lower body negative pressure (LBNP). The instantaneous amplitude modulations (AM) present in heart rate (AMHR) and breathing rate (AMBR) band frequencies of PPG signals were calculated from the high-resolution TFS. Results suggested that the changes (P <; 0.05) in AMBR and especially in AMHR values can be used to detect the blood volume loss at an early stage of 20% LBNP tolerance when compared to the baseline values. The mean percent decrease in AMHR values at 100% LBNP tolerance was 78.3%, 72.5%, and 33.9% for ear, finger, and forehead PPG signals, respectively. The mean percent increase in AMBR values at 100% LBNP tolerance was 99.4% and 19.6% for ear and finger sites, respectively; AMBR values were not attainable for forehead PPG signal. Even without baseline AMHR values, our results suggest that hypovolemia detection is possible with specificity and sensitivity greater than 90% for the ear and forehead locations when LBNP tolerance is 100%. Therefore, the TFS analysis of noninvasive PPG waveforms is promising for early diagnosis and quantification of hypovolemia at levels not identified by vital signs in spontaneously breathing subjects.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:58 ,  Issue: 8 )