LLC converters with automatic resonant frequency tracking based on synchronous rectifier (SR) gate driving signals

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

The purchase and pricing options are temporarily unavailable. Please try again later.
4 Author(s)
Weiyi Feng ; Center for Power Electron. Syst., Virginia Polytech. Inst. State Univ., Blacksburg, VA, USA ; Mattavelli, P. ; Lee, F.C. ; Dianbo Fu

In this paper, a novel switching frequency control scheme to track the resonant frequency point (f0) is proposed. First, the synchronous rectifier (SR) gate driving signals are well tuned with proposed universal adaptive SR driving scheme by eliminating the body diode conduction. Then, the novel pulse width locked loop with digital implementation is presented to minimize the pulse width difference between main switch and well tuned SR gate driving signals, making LLC always operate at f0 point.

Published in:

Applied Power Electronics Conference and Exposition (APEC), 2011 Twenty-Sixth Annual IEEE

Date of Conference:

6-11 March 2011