5 Author(s)
Chun-Kai Chan ; Power Mech. Eng. Dept., Nat. TsingHua Univ., Hsinchu, Taiwan ; Wei-Cheng Lai ; Mingching Wu ; Ming-Yung Wang
more authors

This study reports the design and implementation of a novel capacitive-type micromachined microphone. The design of the microphone is based on the well-known two poly-Si layers micromachining processes. The microphone consists of a rigid diaphragm (the 2nd poly-Si layer), flexible springs (the 1st ply-Si layer), and rigid back plate (the 1st poly-Si layer). In short, the proposed microphone design has four merits, (1) the rigid diaphragm acting as the acoustic wave receiver and moving electrode is realized using the rib-reinforced poly-Si layer, (2) the flexible spring acting as the electrical routing as well as supporter for diaphragm is implemented using the thin poly-Si film, (3) the electrical routing of rigid diaphragm (moving electrode) is through the central poly-via and the flexible spring, and (4) the rigid plate acting as the stationary electrodes and back plate is fabricated using the high-aspect-ratio (HARM) trench-refilled poly-Si. To demonstrate the feasibility, the two poly-Si microphone has been implemented and tested. Typical measurement results show that the open-circuit sensitivity of the microphone was 12.63 mV/Pa ( -37.97 dBV/Pa) at 1 kHz. (the reference sound-level is 94 dB).

Published in:

Sensors Journal, IEEE  (Volume:11 ,  Issue: 10 )

Date of Publication:

Oct. 2011

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.