Close category search window
 

Ambulatory Estimation of Knee-Joint Kinematics in Anatomical Coordinate System Using Accelerometers and Magnetometers

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Liu Kun ; Coll. of Mech. Sci. & Eng., Jilin Univ., Jilin, China ; Inoue, Y. ; Shibata, K. ; Cao Enguo

Knee-joint kinematics analysis using an optimal sensor set and a reliable algorithm would be useful in the gait analysis. An original approach for ambulatory estimation of knee-joint angles in anatomical coordinate system is presented, which is composed of a physical-sensor-difference-based algorithm and virtual-sensor-difference-based algorithm. To test the approach, a wearable monitoring system composed of accelerometers and magnetometers was developed and evaluated on lower limb. The flexion/extension (f/e), abduction/adduction (a/a), and inversion/extension (i/e) rotation angles of the knee joint in the anatomical joint coordinate system were estimated. In this method, since there is no integration of angular acceleration or angular velocity, the result is not distorted by offset and drift. The three knee-joint angles within the anatomical coordinate system are independent of the orders, which must be considered when Euler angles are used. Besides, since there are no physical sensors implanted in the knee joint based on the virtual-sensor-difference-based algorithm, it is feasible to analyze knee-joint kinematics with less numbers and types of sensors than those mentioned in some others methods. Compared with results from the reference system, the developed wearable sensor system is available to do gait analysis with fewer sensors and high degree of accuracy.

Published in:
Biomedical Engineering, IEEE Transactions on  (Volume:58 ,  Issue: 2 )

Date of Publication: Feb. 2011

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.