A Comparison of Three Image Fidelity Metrics of Different Computational Principles for JPEG2000 Compressed Abdomen CT Images

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

8 Author(s)
Kil Joong Kim ; Dept. of Radiat. Appl. Life Sci., Seoul Nat. Univ. Coll. of Med., Seoul, South Korea ; Bohyoung Kim ; Mantiuk, R. ; Richter, T.
more authors

This study aimed to evaluate three image fidelity metrics of different computational principles-peak signal-to-noise ratio (PSNR), high-dynamic range visual difference predictor (HDR-VDP), and multiscale structural similarity (MS-SSIM)-in measuring the fidelity of JPEG2000 compressed abdomen computed tomography images from a viewpoint of visually lossless compression. Three hundred images with 0.67- or 5-mm section thickness were compressed to one of five compression ratios ranging from reversible compression to 15:1. The fidelity of each compressed image was measured by five radiologists' visual analyses (distinguishable or indistinguishable from the original) and the three metrics. The Spearman rank correlation coefficients of the PSNR, HDR-VDP, and MS-SSIM values with the number of readers responding as indistinguishable were 0.86, 0.94, and 0.86, respectively. Using the pooled readers' responses as the reference standard, the area under the receiver-operating-characteristic curve for the HDR-VDP (0.99) was significantly greater than that for the PSNR (0.95) (p <; 0.001) and for the MS-SSIM (0.96) (p = 0.003), and there was no significant difference between the PSNR and MS-SSIM (p = 0.70). In measuring the image fidelity, the HDR-VDP outperforms the PSNR and MS-SSIM, and the MS-SSIM and PSNR are comparable.

Published in:

Medical Imaging, IEEE Transactions on  (Volume:29 ,  Issue: 8 )