Surface loss rates of H and Cl radicals in an inductively coupled plasma etcher derived from time-resolved electron density and optical emission measurements

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

8 Author(s)
Curley, G.A. ; Laboratoire de Photonique et de Nanostructures (LPN)-CNRS, Route de Nozay, Marcoussis 91460, France ; Gatilova, L. ; Guilet, S. ; Bouchoule, S.
more authors

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1116/1.3330766 

A study is undertaken of the loss kinetics of H and Cl atoms in an inductively coupled plasma (ICP) reactor used for the etching of III-V semiconductor materials. A time-resolved optical emission spectroscopy technique, also referred to as pulsed induced fluorescence (PIF), has been combined with time-resolved microwave hairpin probe measurements of the electron density in a pulsed Cl2/H2-based discharge for this purpose. The surface loss rate of H, kwH, was measured in H2 plasma and was found to lie in the 125–500 s-1 range (γH surface recombination coefficient of ∼0.006–0.023), depending on the reactor walls conditioning. The PIF technique was then evaluated for the derivation of kwCl, and γCl in Cl2-based plasmas. In contrast to H2 plasma, significant variations in the electron density may occur over the millisecond time scale corresponding to Cl2 dissociation at the rising edge of the plasma pulse. By comparing the temporal evolution of the electron density and the Ar-line intensity curves with 10% of Ar added in the discharge, the authors show that a time-resolved actinometry procedure using Ar as an actinometer is valid at low to moderate ICP powers to estimate the Cl loss rate. They measured a Cl loss rate of ∼125–200 s-1 (0.03≤γCl≤0.06) at 150 W ICP power for a reactor st- - ate close to etching conditions. The Cl surface loss rate was also estimated for high ICP power (800 W) following the same procedure, giving a value of ∼130–150 s-1 Cl∼0.04), which is close to that measured at 150 W ICP power.

Published in:

Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films  (Volume:28 ,  Issue: 2 )