Real-time ultrasound elasticity imaging for liver RF ablation assessment: Preliminary ex vivo and in vivo animal studies

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

9 Author(s)
Hua Xie ; Philips Res. North America, Briarcliff Manor, NY, USA ; Fernandez, A.T. ; Unmin Bae ; Sheng Xu
more authors

In this study, a real-time compression based ultrasound elasticity imaging prototype was developed and evaluated for liver radio-frequency ablation (RFA) assessment under ex vivo and in vivo conditions. The prototype was implemented on a commercial ultrasound system (iU22, Philips Healthcare) for an L12-5 linear transducer and a C5-1 curvilinear transducer. Under the ex vivo condition, two bovine liver samples were used for L12-5 and C5-1 respectively. Under the in vivo condition, a pig was anesthetized and mechanically ventilated. Ultrasound elasticity imaging experiments were performed during breath-hold in order to reduce respiratory motion artifacts. Post-RFA strain images were compared against several imaging modalities including MRI, contrast-enhanced CT and gross pathology. For the ex vivo case, a Rita Starburst probe (AngioDynamics, Queensbury, NY) was used to perform RFA and induce tissue deformation for strain imaging. Real-time strain images were generated pre- and post-RFA. After the ablation, the liver was imaged by a Panorama 1-T MRI system (Philips Healthcare), then it was dissected along the approximate ultrasound imaging plane for lesion dimension measurement using a caliper. The post-RFA strain images depicted an ablation zone with increased stiffness that was well correlated with the physiological changes observed in the T1-weighted MR image and gross pathology. For the second ex vivo liver sample, the strain image revealed an ablation zone of 4.90 cm ? 2.85 cm, and the MR image and gross pathology showed a zone of 4.56 cm ? 3.24 cm and of 4.91 cm ? 3.65 cm, respectively. For the in vivo study, three different commercial RFA needles were employed: the Covidien (Mansfield, MA) CoolTip single prong and triple-cluster probes, and the Rita Starburst probe. The animal underwent contrast-enhanced CT imaging immediately after RFA. It was then sacrificed and the ablated liver lobes were dissected for ex vivo MRI. All three imaging modalities showed compar- able measurement of lesion dimensions. The triple-cluster Covidien probe and the Rita probe with expanding tines seemed to perform better with elasticity assessment than the Covidien single prong probe. Preliminary results from this study demonstrate that real-time ultrasound strain imaging is potentially a valuable tool for assessing liver RFA. Further technical development of this prototype will advance toward real-time clinical use.

Published in:

Ultrasonics Symposium (IUS), 2009 IEEE International

Date of Conference:

20-23 Sept. 2009