Assessment of Vibrotactile Feedback on Postural Stability During Pseudorandom Multidirectional Platform Motion

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Sienko, K.H. ; Dept. of Mech. Eng., Univ. of Michigan, Ann Arbor, MI, USA ; Vichare, V.V. ; Balkwill, M.D. ; Wall, C.

This study uses frequency-domain techniques and stabilogram diffusion analysis (SDA) to investigate the effect of vibrotactile feedback during continuous multidirectional perturbations of a support platform. Eight subjects with vestibular deficits were subjected to two-axis pseudorandom surface platform motion while donning a multiaxis vibrotactile feedback device that mapped body tilt estimates onto their torsos via a 3-row by 16-column array of tactile vibrators (tactors). Four tactor display configurations with spatial resolutions ranging between 22.5?? and 90??, in addition to the tactors off configuration, were evaluated. Power spectral density functions of body sway in the anterior-posterior (A/P) and medial-lateral (M/L) directions, and transfer functions between platform motion and body sway, were computed at frequencies ranging from 0.0178 to 3.56 Hz. Cross-spectral analysis revealed that the A/P responses were not significantly driven by M/L inputs, and vice versa, thus supporting the notion of independent A/P and M/L postural control. Vibrotactile feedback significantly decreased A/P and M/L spectral power, decreased transfer function gains up to a frequency of 1.8 and 0.6 Hz in the A/P and M/L directions, respectively, and increased phase leads above 0.3 Hz. SDA showed significantly decreased transition time for both A/P and M/L tilts, and decreased transition displacement and short-term diffusion coefficients for A/P tilt. However, the spatial resolution of the tactor displays did not affect subjects' performance, thereby supporting the use of a lower spatial resolution display in future device designs.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:57 ,  Issue: 4 )