Sector-Switching Sonication Strategy for Accelerated HIFU Treatment of Prostate Cancer: In Vitro Experimental Validation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

6 Author(s)
Lorena Petrusca$^*$ ; National Institute for Health and Medical Research U556, Lyon, France ; Rares Salomir ; Lucie Brasset ; FranÇoise Chavrier
more authors

The study investigates a new sonication strategy with high-intensity focused ultrasound (HIFU), aiming for improvement of the original Ablatherm procedure in the prostate cancer treatment. The currently implemented and clinically used method (defined as reference) uses a single-element transducer, operated with 60% duty cycle. To implement the novel strategy, the active surface was split into two sectors, which can be powered either sequentially (for temporal switching) or simultaneously (equivalent to a single-element transducer). Numerical simulations were used to predict the lesion shape and to determine for the novel strategy the best set of treatment parameters among the 99 explored cases. The same pattern for the focal point trajectory was executed irrespectively to the sector activating mode. The theoretical duty cycle reached 100% for the sector switching strategy. The HIFU device was built MRI compatible, and consisted of two mirror symmetrical sectors operating at 3 MHz, shaped as a truncated spherical cap. The two sonication strategies were experimentally tested on fresh samples of degassed porcine liver, using fast MR thermometry (proton resonance frequency shift method with voxel size 0.85 ? 0.85 ? 4.25 mm3, 2 s/dynamic, 0.5?C temperature accuracy, two orthogonal slices). A practical value of 87.5% overall duty cycle could be experimentally implemented. The performance of the two sonication strategies was comparatively assessed based on: cumulated thermal dose derived from MR temperature maps, postoperatory MR morphological images sensitive to tissue contrast changes (inversion-recovery T1-weighted turbo spin-echo, voxel size 0.5 ? 0.5 ? 4 mm3) and postoperatory macroscopic tissue examination. Using a sector-switching sonication strategy for prostate cancer treatment-induced lesions of similar size and shape as for the reference approach. When considering the available reserve of duty cycle and the exact lesion size, we concluded - he treatment time was reduced by 20% with the new sector switching strategy at equal performance. Further in vivo studies are considered mandatory for preclinical validation.

Published in:

IEEE Transactions on Biomedical Engineering  (Volume:57 ,  Issue: 1 )