By Topic

Performance of Monocrystalline Diamond Radiation Detectors Fabricated Using TiW, Cr/Au and a Novel Ohmic DLC/Pt/Au Electrical Contact

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

10 Author(s)
Galbiati, A. ; Diamond Detectors Ltd., Poole, UK ; Lynn, S. ; Oliver, K. ; Schirru, F.
more authors

We investigated the performance of synthetic high purity monocrystalline diamond radiation detectors fabricated with TiW, Cr/Au and a novel metallization technique utilising diamond-like carbon tunnelling junction and Pt/Au as electrical contacts. The investigation was carried out under irradiation with 60Co gamma-rays, 90Sr electrons and 241Am alpha-particles. The experimental results with respect to I-V dark current levels, irradiation photocurrent, signal-to-noise ratio and time response have been compared and discussed. Results show an ohmic behaviour of the DLC/Pt/Au contact, a charge collection efficiency of 100% at an applied electric field of 0.377 V/ mum for all electrical contacts (under 90Sr electrons irradiation) at a correspondent dark current value of less than a picoAmpere. The single crystal CVD DLC/Pt/Au diamond radiation detector reported here shows spectroscopic energy resolution of 1.1% at an applied voltage of +450 volts (0.9 V/mum) under 5.5 MeV alpha particle irradiation. No dasiamemorypsila or dasiapumpingpsila effect was observed for the DLC/Pt/Au contact at positive bias; the signal was also stable (fluctuations below 0.5%) and reproducible under 60Co irradiation, with a signal-to-noise ratio > 10000:1 and a linearity in the dose rate response.

Published in:

Nuclear Science, IEEE Transactions on  (Volume:56 ,  Issue: 4 )