Close category search window
 

Characterization of Ageing for MV Power Cables Using Low Frequency Tan δ Diagnostic Measurements

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Hernandez-mejia, J. ; Sch. of Electr. & Comput. Eng. (ECE), Georgia Inst. of Technol., Atlanta, GA ; Harley, R. ; Hampton, N. ; Hartlein, R.

This paper describes very low frequency (VLF) tan delta experiments performed on field-aged and non-aged distribution medium voltage (MV) cable samples. The field aged samples constitute a uniform set of Cross-linked Polyethylene (XLPE) of 15 kV unjacketed cables removed from the same service area having experienced similar operating and ageing conditions. The non-aged samples are a diverse set of crosslinked polyethylene (XLPE) and water tree retardant cross-linked polyethylene (WTRXLPE) cables of 15 kV and 25 kV and Ethylene Propylene Rubber (EPR) cable of 25 kV. The experiments are designed to contribute in understanding, time, voltage and discharge time dependence of Tan delta diagnostic measurements at VLF of 0.1 Hz. Results help in clarifying issues that arise when characterizing MV cable insulation by Tan delta diagnostic measurements. The issues include time-on-test, voltage level as a diagnostic tool, diagnostic features, and reproducibility and repeatability of the measurements. The paper shows that higher insulation losses, non-linearity, hyteresis, and variation in voltage and time of Tan delta diagnostic measurements at VLF are indicators that can be used to properly characterize the insulation and enhance the diagnosis.

Published in:
Dielectrics and Electrical Insulation, IEEE Transactions on  (Volume:16 ,  Issue: 3 )

Date of Publication: June 2009

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.