Eigenleads: ECG Leads for Maximizing Information Capture and Improving SNR

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Finlay, D.D. ; Sch. of Comput. & Math., Univ. of Ulster, Newtownabbey, UK ; Nugent, C.D. ; Donnelly, M.P. ; Lux, R.L.

There is currently much interest in exploring new ways to optimize ECG acquisition. In the current study, we have investigated optimal configurations of ECG leads with respect to: (1) best signal magnitude (maximal signal variance) and (2) best reconstruction of the total body surface potential distribution and the 12-lead ECG. Principal component analysis was applied to a set of 117-lead body surface potential maps (BSPMs) recorded from 559 subjects. Three bipolar leads, referred to as "eigenleads," were identified from the extrema on the resulting eigenvectors. Recording sites for the three leads were largely located in the precordial region. The magnitude of the signals recorded from the eigenleads was calculated on a set of 185 unseen subjects. The accuracy of the eigenleads in the reconstruction of BSPMs and the 12-lead ECG was also assessed for each subject. These results were compared to existing limited lead systems. It was found that, when compared to conventional leads, eigenleads could be used to increase signal strength (rms voltage) by 27.9%, 39.0%, and 20.3% for P-waves, QRS segments, and STT segments, respectively. Although the eigenleads were not able to reconstruct total body surface information as well as the 12-lead ECG (24.4 ?? V versus 20.2 ?? V), the eigenleads did perform comparably with other limited lead systems in the estimation of the 12-lead ECG. In particular, the eigenleads performed well in the reconstruction of precordial leads in comparison to the EASI lead system and a limited lead system made up of a subset of precordial leads. The proposed leads are a suitable alternative limited leads system, and can be used to improve SNR. More work is needed to test the practicality of such leads.

Published in:

Information Technology in Biomedicine, IEEE Transactions on  (Volume:14 ,  Issue: 1 )