By Topic

Compton scatter and X-ray crosstalk and the use of very thin inter-crystal septa in high resolution PET detectors

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Levin, C.S. ; Sch. of Med., California Univ., Los Angeles, CA, USA ; Tornai, M.P. ; Cherry, S.R. ; MacDonald, L.R.
more authors

To improve spatial resolution, PET systems are being developed with finer detector elements. Unfortunately, using smaller crystal sizes increases inter-crystal Compton scatter and bismuth X-ray and (to a lesser degree) electron escape crosstalk, causing positioning errors that lead to degradation of image contrast. The authors investigated the use of extremely thin (⩽300 μm) lead strips for passive shielding of this inter-crystal crosstalk. Using annihilation photons and small (2 and 3 mm wide) BGO crystals in coincidence, crosstalk studies were performed with either two small adjacent crystals (1-D) or one crystal inside a volume of BGO (2-D). The fraction of Compton scattered events from one crystal into an adjacent one was reduced, on average, by a factor of 3.2 (2.2) in the 1-D experiment and by a factor of 3.0 (2.1) in 2-D, with a 300 (150) μm thick lead strip in between the crystals and a 300-700 keV energy window in both crystals. The authors could not measure a reduction in bismuth X-ray crosstalk with the use of lead septa because of the production of lead X-rays. The width of the coincident point spread function was not significantly different for the 1- and 2-D studies, with or without the different thickness septa in place. These results indicate that intercrystal crosstalk does not affect the positioning resolution. A simple insertion of very thin lead strips may significantly reduce the inter-crystal scattering crosstalk of a high resolution PET system, thereby ultimately improving image contrast, without introducing a dead area

Published in:

Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE  (Volume:2 )

Date of Conference:

21-28 Oct 1995