Reduced adhesion of human blood platelets to polyethylene tubing by microplasma surface modification

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

10 Author(s)
Lauer, J.L. ; Plasma Processing and Technology Laboratory and Department of Electrical & Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706 ; Shohet, J.L. ; Albrecht, R.M. ; Pratoomtong, C.
more authors

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1063/1.1786668 

A hollow-cathode microplasma modified the lumenal surface of small-diameter polyethylene (PE) tubing. A microwave cavity diagnostic was used to measure the density of the microplasma. Plasma light output was observed with a monochromator at various positions along the PE tube to assess uniformity. Treatment effectiveness was evaluated by measuring the variation in capillary rise at various positions along the tubing. A correlation between the properties of the inner surface of the PE tubing and the emitted light intensity was found. A poly(ethylene oxide) surfactant was immobilized to the lumenal surface of the PE tubing with an argon microplasma discharge. To test hematocompatibility, an in vitro blood-flow loop circulated heparinized human blood through both a plasma-treated and -untreated PE tubes, simultaneously. After blood exposure, the tubes were examined with a scanning electron microscope to assess the density of adhering platelets along the length of the tubes. By modifying the plasma parameters, the uniformity of the microplasma treatment along the tubing can be optimized.

Published in:

Journal of Applied Physics  (Volume:96 ,  Issue: 8 )

Date of Publication:

Oct 2004