Two 1H-nuclear magnetic resonance methods to measure internal porosity of bone trabeculae: By solid–liquid signal separation and by longitudinal relaxation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

7 Author(s)
Fantazzini, Paola ; University of Bologna, Department of Physics, Viale Berti Pichat 6/2, 40127 Bologna, Italy ; Bortolotti, Villiam ; Brown, Robert J.S. ; Camaiti, Mara
more authors

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1063/1.1630374 

Parameters related to pore-space structure of the trabeculae in cancellous bone are difficult to determine quantitatively, but they can be important to characterize changes induced in bone by diseases such as osteoporosis. We present two nuclear magnetic resonance (NMR) methods to measure the internal porosity φtrab of the trabeculae, based on two different measurements of the fraction of intratrabecular and intertrabecular pore-space in animal femur samples. These procedures have been developed within the more general framework of the NMR studies for fluids in porous media. In the first method we use the ratio between the amount of collagen (solid-like) 1H and that of the fluids in the samples. In the second, which can be applied only on defatted and water saturated samples, we use the distributions of longitudinal relaxation times. The φtrab values obtained are constant for porosity φ of the samples over the range 40%–70%, with each method giving φtrab=(29±4)%, which is consistent with the only data available, the porosity of related cortical bone. The traditional parameter bone volume fraction is simply given by (1-φ)/(1-φtrab). © 2004 American Institute of Physics.

Published in:

Journal of Applied Physics  (Volume:95 ,  Issue: 1 )