Spectral composition of heart sounds before and after mechanical heart valve implantation using a modified forward-backward Prony's method

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Sava, H.P. ; Signals & Syst. Group, Edinburgh Univ., UK ; McDonnell, J.T.E.

This paper investigates the impact of the lung-thorax and heart-valve system on the overall spectral composition of the externally recorded heart sounds. The study concentrates on the case of the first and the second heart sounds for normal patients and patients before and after implantation of a mechanical valve in the mitral or aortic position. The analysis is performed using a modified forward-backward overdetermined Prony's method (MFBPM) which uses a forward-backward mean filter and a modified procedure for estimating the position of the signal poles. In terms of the normalized cross-correlation coefficient, this method has an average modeling accuracy of 99.62% for representing the first and second heart sounds and an average least square time-domain error of 0.43%. Results obtained from 40 subjects show that the condition of the native mitral or aortic valve affects mostly the distribution of the amplitudes of the spectral components, whereas the number of the spectral components or their respective relative energy remains more or less unchanged. It has been found that the amplitudes of frequency components in the range 120-250 Hz are more affected by abnormalities of native mitral valves. Furthermore, in the case of the second heart sound the region 250-400 Hz has been found to be more affected by abnormalities in the aortic valve. It has also been found that the mechanical prosthetic heart valve affects mostly the spectrum beyond 400 Hz. A clear difference has been observed in the frequency spectrum above 400 Hz between both normally and abnormally functioning native valves and normally functioning mechanical valves. Preliminary results in some malfunctioning cases of mechanical prosthesis suggest that spectral components beyond 400 Hz can be used to monitor the condition of these prostheses.

Published in:
Biomedical Engineering, IEEE Transactions on  (Volume:43 ,  Issue: 7 )

Date of Publication: July 1996

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.