Cart (Loading....) | Create Account
Close category search window
 

Estimation of the noise contributions from blank, transmission and emission scans in PET

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Holm, S. ; Dept. of Nucl. Med., Nat. Univ. Hospital, Copenhagen, Denmark ; Toft, P. ; Jensen, M.

This work determines the relative importance of noise from blank (B), transmission (T) and emission (E) scans in PET using a GE Advance scanner on a 20 cm cylinder, a brain phantom, and a torso-like ellipse (18/35 cm) with examples of human scans (brain O-15 water and F-18 FDG, heart FDG). Phantom E scans were acquired in both 2D and 3D modes as decay series with C-11 or F-18 over 3-6 decades of noise equivalent counts (NEC). B and T scans were made using two pin sources (389+134 MBq) with times 16-32,768 sec. In humans only a limited subset was available. In homogeneous phantoms normalized variance (var) was estimated from pixel distributions in single images. In other objects, including the human studies, calculations were performed on differences of paired images. In all cases a fit was made to a simple noise model. The cylinder data shows expected relations of T to B noise proving the adequacy of B scan times <30 min for most purposes. For cylinder and brain phantom, contour plots are provided for var(E,T). In a typical 3D O-15 water study with 0.5 M counts per central slice, a 10 min T-scan ensures that var(T)<0.1*var(E). Using 10 min T scan for a static 3D FDG brain study of 10 min having 5 M counts yields equal E and T variance contributions. In human body scans T noise has a relative larger importance and is often dominated by effects of line artefacts from (clusters of) zeros in the T-scan, not included in the simple model

Published in:

Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE  (Volume:3 )

Date of Conference:

21-28 Oct 1995

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.