Calibration experiments of 3He neutron detectors for analyzing neutron emissivity in the hot-ion mode on the GAMMA 10 tandem mirror

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

16 Author(s)
Kohagura, J. ; Plasma Research Centre, University of Tsukuba, Ibaraki 305-8577, Japan ; Cho, T. ; Hirata, M. ; Watanabe, H.
more authors

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1063/1.1534402 

Under the international fusion cooperating research, 3He neutron detectors in the GAMMA 10 tandem mirror are calibrated by the use of a 252Cf spontaneous fission neutron source (8.96×104n/s). The calibration experiments are carried out with a “rail system” placed along the magnetic axis of the GAMMA 10 central-cell region, where hot ions in the plasma experiments with the bulk temperatures of ∼10 keV are produced. As compared to a previous neutron monitoring system with a BF3 detector in GAMMA 10, the present 3He systems are designed with about two orders-of-magnitude higher neutron-counting efficiency for analyzing a neutron emissivity from the plasmas in a single plasma discharge alone. Two 3He systems are installed near the middle and the end of the central cell so as to identify the central-cell hot-ion axial profile. The filling pressure of 3He, the effective length, and the diameter of the detector are designed as 5 bar, 300 mm, and 50 mm, respectively. The detector output spectra are carefully analyzed by the use of a preamplifier, a shaping amplifier, as well as a multichannel analyzer for each 3He detector. In the present article, the neutron-counting data from the two 3He detectors due to the on-axis 252Cf scan are interpreted in terms of the d-2 intensity dependence (d being the distance between the detector and the neutron source) as well as the effects of the central-cell magnetic coils and the other machine structural components. © 2003 - American Institute of Physics.

Published in:

Review of Scientific Instruments  (Volume:74 ,  Issue: 3 )