A nanosecond near-infrared step-scan Fourier transform absorption spectrometer: Monitoring singlet oxygen, organic molecule triplet states, and associated thermal effects upon pulsed-laser irradiation of a photosensitizer

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Andersen, Lars Klembt ; Department of Chemistry, University of Aarhus, Langelandsgade 140, DK-8000 Århus, Denmark ; Ogilby, Peter R.

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1063/1.1517148 

A step-scan Fourier transform (FT) near infrared (IR) spectrometer has been used to record nanosecond time-resolved absorption spectra of singlet molecular oxygen (a1Δg→b1Σg+) created by pulsed-laser irradiation of a photosensitizer dissolved in a solvent. In addition to oxygen’s a→b transition at ∼5200 cm-1, other laser-induced changes in absorbance can be monitored over the spectral range ∼4000–11 000 cm-1. These include transients derived from the singlet oxygen sensitizer, and examples are provided with triplet state absorption spectra of several molecules in benzene as well as water. In this report, issues pertinent to the use of a step-scan FT spectrometer to monitor weak laser-induced near-IR signals are discussed. Specifically, key modifications to a commercially available instrument are described, and the relevant sources of noise from electronic components are outlined. Transient laser-induced thermal effects such as thermal lenses and temperature-dependent shifts in solvent absorption bands can also interfere with the detection of a given signal, and these complications are likewise described. The significance of these issues is apparent when monitoring oxygen’s a→b transition in D2O, a scenario in which the present detection limits of this technique are embodied. Much of the information in this report transcends the specific problem of singlet oxygen detection, however, and addresses issues general to the use of a step-scan FT spectrometer for time-resolved IR measurements. © 2002 American Institute of Physics.

Published in:

Review of Scientific Instruments  (Volume:73 ,  Issue: 12 )