6 Author(s)
Sreenivasan, Ramaswamy ; Institute for Systems Research and Department of Chemical Engineering, University of Maryland, College Park, Maryland 20742 ; Gougousi, Theodosia ; Xu, Yiheng ; Kidder, John
more authors

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1116/1.1406159 

Run to run control with an Internal Model Control (IMC) approach has been used for wafer state (thickness) control in the tungsten chemical vapor deposition (CVD) process. The control implementation was preceded by establishing a stable wafer state thickness metrology using in situ mass spectrometry. Direct reactor sampling was achieved from an Ulvac ERA-1000 cluster tool module during the H2/WF6 W CVD process at 0.5 Torr for temperatures 350–400 °C using a 300 amu closed ion source Inficon Transpector system. Signals from HF product generation were used for in-process thickness metrology and compared to ex situ, postprocess thickness measurements obtained by microbalance mass measurements, providing a metrology accuracy of about 7% (limited primarily by the very low conversion efficiency of the process used, ∼2%–3%). A deliberate systematic process drift was introduced as a -5 °C temperature change for each successive wafer, which would have led to a major (∼50%) thickness decrease over ten wafers in an open loop system. A robust run to run (RtR) control algorithm was used to alter the process time in order to maintain constant HF sensing signal obtained from the mass spectrometer, resulting in thickness control comparable to the metrology accuracy. The efficacy of the control algorithm was also corroborated by additional experiments that utilized direct film weight measurements through the use of the microbalance. A set of simulations in Matlab® preceded the control implementation and helped in tuning the controller parameters. These results suggest that in situ chemical sensing, and particularly mass spectrometry, provide the basis for wafer state metrology as needed to achieve RtR control. Furthermore, since the control was consistent with the metrology accuracy, we anticipate significan- - t improvements for processes used in manufacturing, where conversion rates are much higher (40%–50%) and corresponding signals for metrology will be much larger. © 2001 American Vacuum Society.

Published in:

Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures  (Volume:19 ,  Issue: 5 )