By Topic

High-frequency noise measurements in spin-valve devices

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Stutzke, N.A. ; Boise State University, Boise, Idaho 83725 ; Burkett, S.L. ; Russek, S.E.

Your organization might have access to this article on the publisher's site. To check, click on this link:http://dx.doi.org/+10.1116/1.1582458 

High-frequency magnetic noise in magnetoresistive devices being developed for read-sensor and magnetic random access memory applications may present fundamental limitations on the performance of submicrometer magnetic devices. High-frequency magnetic noise (HFN) arises from intrinsic thermal fluctuations of the device magnetization. High-frequency noise spectroscopy provides a powerful tool to characterize the dynamics and response of small multilayer magnetic devices. In this study, the noise characteristics of micrometer-dimension spin valves have been investigated at frequencies in the range 0.1–6 GHz. At frequencies below this range 1/f noise dominates. HFN measurements, as a function of bias current and longitudinal magnetic field, are obtained for IrMn exchange-biased spin valves using a 50 GHz spectrum analyzer, low-noise amplifier, and a microwave probing system. The magnetic noise is obtained by taking the difference between the noise spectrum of the device in a saturated and unsaturated state. The data can be fit to simple models that predict the noise power to be proportional to the imaginary part of the free-layer magnetic susceptibility. There are some important differences between the high-frequency noise measurements and direct measurements of the device susceptibility (both at the device and wafer level). The noise measurements show a smaller damping parameter (a smaller ferromagnetic resonance linewidth) and additional features due to the presence of nonuniform modes. © 2003 American Vacuum Society.

Published in:

Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films  (Volume:21 ,  Issue: 4 )