Comparison of performances of several types of classical controller in automatic generation control for an interconnected multi-area thermal system

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Nanda, J. ; Dept. of Electr. Eng., IIT Delhi, New Delhi ; Saikia, L.C.

This paper presents automatic generation control (AGC) of interconnected two equal area and three unequal area thermal systems provided with single reheat turbine and generation rate constraints of 3% per minute. A maiden attempt is made to apply integral plus double derivative (IDD) controller in AGC. Controller gains in the two area system are optimized using classical approach whereas in the three area system controller gains and governor speed regulation parameters (Ri) are simultaneously optimized by using a more recent and powerful evolutionary computational technique called bacterial foraging (BF) technique. Investigations reveal on comparison that Integral (I), proportional-integral (PI), integral-derivative (ID), or proportional-integral-derivative (PID) all provide more or less same response whereas integral-double derivative (IDD) controller provides much better response. Sensitivity analysis reveals the robustness of optimum gains of IDD controllers and optimum values of speed regulation parameters at nominal loading condition to wide changes in system parameters such as loading condition, inertia constant (H), reheat time constant (Tr) and reheat coefficient (Kr) from their nominal values. The system performance is examined considering 1% step load perturbation in area1.

Published in:

Power Engineering Conference, 2008. AUPEC '08. Australasian Universities

Date of Conference:

14-17 Dec. 2008

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.