This paper presents the application of a complex adaptive linear neural network (CADALINE) in tracking the fundamental power system frequency. In this method, by using Park transformation in addition to producing a complex input measurement, the decaying DC offset is eliminated. As the proposed method uses first-order differentiator to estimate frequency changes, a Hamming filter is used to smoothen the response and cancel high-frequency noises. The most distinguishing features of the proposed method are the reduction in the size of observation state vector required by a simple adaptive linear neural network (ADALINE) and increase in the accuracy and convergence speed under transient conditions. This paper concludes with the presentation of the representative results obtained in numerical simulations and simulation in PSCAD/EMTDC software.
Published in:
Power and Energy Conference, 2008. PECon 2008. IEEE 2nd International
Date of Conference: 1-3 Dec. 2008