Close category search window
 

Power Quality Assessment of Distributed Generator Grounding Method

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Sutherland, P.E. ; EPRI Solutions, Inc., Schenectady, NY ; Short, T.A.

The objective of this project was to assess the specific transformer grounding and connection methods that are used at the subject utility for distributed generators (DGs) and provide a risk assessment in terms of potential impact, ways to minimize the impact, and site specific screening criteria for additional protection that may be required for DG interconnection. The utility has standardized on a grounded wye-grounded wye transformer connection for customers connected to their distribution system. When a backup generator exists in the customer's facility that could be paralleled with the utility system, a contactor is installed on the neutral to ground connection on the generator. This contactor is opened at any time that the generator is paralleled. The utility is considering remotely dispatching these distributed generation assets in times of peak load in the future. This will require the generators to run paralleled for extended periods of time. Grounding practices for auxiliary generators were evaluated, and simulations of both steady-state and fault conditions were conducted. The most critical factors were found to be assuring that the generator ground switch was closed during islanding and that the overvoltage protection operates correctly to isolate the generator during fault conditions. Recommendations for overvoltage protection and testing were developed based upon the results.

Published in:
Industry Applications, IEEE Transactions on  (Volume:45 ,  Issue: 1 )

Date of Publication: Jan.-feb. 2009

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.