The role of the drain wire in modern foil cable shields

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Hoeft, L.O. ; BDM Int., Inc., Albuquerque, NM, USA ; Estes, J.C.

Theoretical and experimental analysis of a wide range of shields that combine an electrically thin cylindrical shield with a drain wire/current diverter shows that the surface transfer impedance can be characterized as a solid foil shield in parallel with the impedance of the drain wire. The drain wire/current diverter should be modeled as an inductor and a frequency-dependent resistor in series. The resistance is frequency-dependent because of skin depth effects. Neglecting high-frequency aperture coupling, the surface transfer impedance of a foil shield with drain wire can be characterized in three frequency regimes. At low frequencies, the transfer impedance is determined by the resistance of the drain wire. At intermediate frequencies, the resistance of the drain wire increases due to skin depth and inductive effects. For most cable shields, the skin depth effect will dominate. At higher frequencies, for cable samples that use good (circumferential) shield termination techniques, the surface transfer impedance is determined by the transfer impedance of the foil shield

Published in:

Electromagnetic Compatibility, 1993. Symposium Record., 1993 IEEE International Symposium on

Date of Conference:

9-13 Aug 1993